How do I set the time on a DSC 1832?
Instructions
- Press the * button, followed by 6.
- Enter your system’s master code.
- Press 1 to Select Time and Date programming.
- If you have a Full Message LCD Keypad, use the < or > keys to scroll to the menu options and press *.
- Using the number keys, enter the time in HH:MM format and date in MM:DD:YY format.
Can you change DSC 1616 1832 or 1864 Delay times?
How do I change DSC 1616, 1832, or 1864 delay times?
- Press *8-installer code to go into programming.
- Enter 005.
- The system will then want a two digit partition number.
- First, enter the 3 digit entry delay 1 in seconds.
- Then, the 3 digit entry delay 2 in seconds.
- Finally, the 3 digit exit delay in seconds.
How do I factory reset my DSC 1832?
Time to factory reset the system. To do this you have to short the zone 1 pin (not the z1 common pin) with the PGM1 pin. Thus, you have to ground Z1 to PGM and power the system up for 10 seconds and then power it off, remove the jumper and then power it back on.
How do I bypass DSC 1832?
How to Bypass a Zone on a DSC Power Series Security Alarm Panel
- The System Must be disarmed prior to proceeding.
- Press the * Key.
- Press the 1 Key.
- Use the > key to scroll to the zone you wish to bypass.
- Press the * Key on the appropriate zone.
- A “B” should appear next to the zone when the system is bypassed.
How do I delete a zone on DSC 1832?
More videos on YouTube
- Enter wireless programming. Start from the main screen of your push-button keypad.
- Access delete zone menu. On your keypad, enter [901].
- Delete the zone. Use the arrow keys (< & >) to find the 3-digit Zone Number of the zone you want to delete.
- Return to main screen.
How do I set the date and time on a DSc 1616?
To set the date and time on a DSC 1616, 1832 or 1864 you will go to your keypad and type *6 + 4-digit Master Code. You will then press 1 to get to the date and time entrance section.
Is there a user manual for the pc1616 pc1832/pc1864?
PC1616/PC1832/PC1864 User Manual WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read. PC1616/PC1832/PC1864 User Manual
Where can the pc1616/1832/1864 alarm system be used?
WARNING: This equipment, PC1616/1832/1864 Alarm System shall be installed and used within an environment that provides the pollution degree max 2 and over-voltages category II non-hazardous locations, indoor only.
Where will the keypad(s) be mounted?
The keypad(s) will be mounted in a convenient location inside the protected premises close to the entry/ exit door(s). The security system has several zones of area protection and each of these zones will be connected to one or more sensors (motion detectors, glassbreak detectors, door contacts, etc.).