What are the data center construction requirements?

What are the data center construction requirements?

Capacity: The floorplan of the data center must have enough room to house all servers and equipment for current and perceived future use. Disaster Tolerant: The data center facility must be able to resist natural disasters and calamities such as earthquakes, floods, snowstorms, tornados, etc.

What are the standards for data center infrastructure?

The most widely adopted standard for data center design and data center infrastructure is ANSI/TIA-942. It includes standards for ANSI/TIA-942-ready certification, which ensures compliance with one of four categories of data center tiers rated for levels of redundancy and fault tolerance.

What floor should a data center be on?

You want your data center on the top floor. You might not be competing for mahogany row but for the inner space (leave the windows for the execs). But you need to watch floor weight load capacity in upper floors. Typical office space designs of 75 lbs./sq.

How much power is required for a data center?

Some of the world’s largest data centers can each contain many tens of thousands of IT devices and require more than 100 megawatts (MW) of power capacity—enough to power around 80,000 U.S. households (U.S. DOE 2020).

What are operational standards for a data center?

Operational Standards ISO 9000 – Quality System. ISO 14000 – Environmental Management System. ISO 27001 – Information Security. PCI – Payment Card Industry Security Standard.

How do you design a good data center?

Data Center Design: 6 Important Tips to Consider

  1. Leave Room for Growth. Investing in a data center is going to be extremely costly.
  2. Plan for the Support Team.
  3. Optimize Data Center Cooling.
  4. Don’t Neglect Physical Security.
  5. Focus on Proper Wiring from the Beginning.
  6. Plan Properly for Your Data Center Design.

What voltage do data centers use?

A server may have an electric plug rated for 110 or 120 volts (but can run at differing levels of voltage). A higher number is better since this achieves better electrical efficiency. Many of the household devices we use every day run at 120 volts.

How many kWh does a data center use?

90 billion kilowatt-hours
In 2017, US based data centers alone used up more than 90 billion kilowatt-hours of electricity. To give some perspective on how much energy that amounts to, it would take 34 massive coal-powered plants generating 500 megawatts each to equal the power demands of those data centers.

Do data centers meet the operational and capacity requirements?

Data centers seldom meet the operational and capacity requirements of their initial designs. The principal goals in data center design are flexibility and scalability, which involve site location, building selection, floor layout, electrical system design, mechanical design and modularity.

What are the data center design and infrastructure standards?

Data center design and infrastructure standards can range from national codes (required), like those of the NFPA, local codes (required), like the New York State Energy Conservation Construction Code, and performance standards like the Uptime Institute’s Tier Standard (optional).

What are the principal goals of data center design?

The principal goals in data center design are flexibility and scalability, which involve site location, building selection, floor layout, electrical system design, mechanical design and modularity.

What skills do you need to design a data center?

Design Process The design stages for the data center usually take the skills of Architects, Accountants, Structural, Mechanical, Electrical, HVAC, System, and Network engineers, Project managers, and Procurement personnel.