Anything reading between 2 megohms and 1000 megohms is usually considered a good reading, unless other problems have been noted. Anything less than 2 megohms indicates an insulation problem.

What is an acceptable reading for insulation resistance?

Insulation resistance should be approximately one megohm for each 1,000 volts of operating voltage, with a minimum value of one megohm. For example, a motor rated at 2,400 volts should have a minimum insulation resistance of 2.4 megohms.

What is the megger reading in a dead short wiring insulation?

The reading is noted. If the megger pointer shows the infinity reading, it shows the best insulation. When the reading is less than infinity, it shows uncertain value of insulation. While zero reading shows the short circuit condition of the circuit.

What is the megger value of cable?

1. IR Values For Electrical Apparatus & Systems

Max.Voltage Rating Of Equipment Megger Size Min.IR Value
600 Volts 1,000 Volts 100 MΩ
5 KV 2,500 Volts 1,000 MΩ
8 KV 2,500 Volts 2,000 MΩ
15 KV 2,500 Volts 5,000 MΩ

How do you test a wire with a megger?

Clamp the alligator clip on one of the megger probes to the wire or cable, touch the other probe to the exposed conductor and press the test button. The megger will generate a current between the probes, and the meter will record the resistance of the jacket to the flow of the current.

How do you test wire insulation with a Megger?

How do you test a wire with a Megger?

How do you Megger a single wire?

How do you megger a 3 phase motor?

How to Test a Three-Phase Motor With a Megger

  1. Turn off the power supply to the motor, usually accomplished by switching the circuit breaker.
  2. Place one megger probe to the any mounting bolt on the breaker box to test for grounding continuity, then touch the other probe to a motor terminal.

What should the resistance be on a Megger?

If the megger reads a resistance under 1 (1,000 ohms) on your meter after the initial 60-second interval, the cable has failed and the cable should be removed. If the megger reads a resistance between 1-1.25 on your meter, then the cable passes. Any reading above 1.25 is considered excellent.

How many megohms is a full scale Megger?

At one time this full scale was typically 2000-4000 megohms, today that varies with the manufacture some meggers now read into gigohms and teraohms. One item to consider is comparison readings, such as a 3-wire circuit “L1” reads 2000 megohms; “L2” reads 200 megohms and “L3” reads 2000 megohms.

What is a Megger test on a cable?

A megger sends voltage through a cable and measures any current leakage in megohms (1,000 ohms). Routine megger tests of aged electrical cable is a prudent way to ensure your circuits are safe from arc faults that can cause circuits to be blown, and safe from fire or electrical shock.

How many megohms is a minimum reading?

Minimum readings are published in NETA specifications. The often-quoted one (1) megohm is, in my opinion a mistake, 5 megohm would be a minimum under certain conditions (buried cable, emergency situations on 208/120 VAC systems). 50 megohms is a minimum we prefer with 100 megohms being the norm.