Where do you put shaver socket in bathroom?

Where do you put shaver socket in bathroom?

Providing the Shaver socket is reduced to 110V it should go in zone 2 or preferably, zone 3, never in zone 1. Also it’s worthy to note that there should be no 240V sockets in the bathroom at all.

How high should a shaving socket be?

The 450mm to 1200mm band is the generally accepted band to satisfy Part M. Or it is stated as ONE WAY of satisfying the requirements.

Can you have a socket in a toilet?

No problem as long as it’s a flush socket. Hopefully you mean in the room containing the toilet and not in the toilet itself – that would be novel! No problem as long as it’s a flush socket.

Can you run a shaver socket off a ring main?

Shaver Sockets can be installed either by connecting to a ring main with junction box, or from an earthed lighting socket.

Why are shaver sockets allowed in bathrooms?

1 Answer. UK shaver sockets are not a lower voltage, but the ones in bathrooms include an isolating transformer and thermal cutout so that neither wire of the shaver has any voltage to earth (so a shock to earth is impossible) and the socket cannot be used for more powerful appliances.

Does shaver socket need isolator?

The shaver socket does not need an isolator. 2. The fan need to be of a low voltage type, the isolator and transformer are fitted outside the bathroom, the isolator is normally placed above the door and often the transformer in the loft.

Why are shaver sockets in the bathroom safe?

The output is 110 volts and the middle of that winding on the transformer is connected to ground. That means that the 2 outputs are only 55 volts from earth and that gives a much smaller chance of getting electrocuted than the 240V mains supply.

What voltage is a shaver socket?

A shaver socket-outlet conforming to BS 4573 has a restricted continuous current rating of 200 mA for use on voltages of 200 V to 250 V a.c. only. The shaver socket-outlet incorporates a current limiting device, other than a fuse, which may be of either the manually-resetting or the self-resetting type.

Can you put an electric socket in a downstairs toilet?

No problem with sockets in a utillity at all, recommendation that sockets are minimum of 300mm from sink. No need to worry about bathroom zones as there is no bath or shower in the room.

Is a toilet a special location?

Bathrooms are considered to be a ‘special location’ for electrical goods, and special care and attention needs to be taken when placing them in a room. It’s important that any of these appliances are placed in their designated bathroom electrical zone to eliminate any threat that they could potentially cause.

Does a shaver socket need an RCD?

An RCD offers no additional protection for a shaver socket. The shaver socket has a transformer inside and the secondary winding is isolated from earth.

Are shaver sockets earthed?

Both types of shaver socket-outlet may be either Class I construction (having metal parts required to be earthed) or Class II construction (having no exposed metal parts required to be earthed). A shaver socket-outlet with a transformer is called a shaver supply unit.