What is the maximum head offset allowed for the size 4 Secur-fit advanced stem?
Secur-Fit Advanced Monolithic Neck trial, 132 Degree (Silver) 1601-XX132 Page 13 +5mm heads are the maximum head offset allowed for the size 4.
What is the purpose of the normalization patterns on the anterior and posterior aspects of the proximal part of the Secur-fit advanced stem?
The Secur-Fit Advanced system offers two neck angles – 127 degrees and 132 degrees – which allows flexibility in adjusting offset intra-operatively. In addition, normalization patterns on the anterior and posterior aspects of the proximal end of the stem facilitate press-fit stability and load transmission.
What is a fit and fill stem?
The fit-and-fill (FF) stem is designed to fill the proximal femoral canal and obtain proximal fixation to the entire stem surface [10], [11]. In contrast, the tapered-wedge (TW) stem is designed to obtain initial stability via fixation in the mediolateral plane or via three-point fixation [8].
What is PureFix ha?
PureFix HA Stryker’s proprietary hydroxylapatite (HA) coating has been a consistent feature of our hip portfolio since it was first implanted in 1987. Trident II HA shells continue this legacy, incorporating approximately 50μm thick coating of PureFix HA over a roughened plasma spray titanium surface.
What is a bipolar hip replacement?
This surgical procedure replaces the head of a damaged femur with an implant designed to stabilize the femur and restore hip function. Unlike total hip replacement, in which both the ball of the femur and the hip socket are replaced, in this procedure, only the ball is replaced.
What is Stryker Accolade 2 made of?
Stryker uses TMZF for its Accolade product, which includes a mix of titanium, molybdenum, iron and zirconium. The Accolade systems use several neck and stem components that are intended to be interchangeable to help surgeons with custom-fit designs rather than the traditional design that uses only one larger piece.
What are Stryker implants made of?
It’s made from polyethylene, a type of plastic designed to increase range of motion, improve joint stability and reduce the risk of wear. Stryker also sells numerous femoral components, including press-fit stems, cemented stems and revision components.
What is the SECUR-fit advanced system?
The Secur-Fit Advanced system offers two neck angles – 127° and 132° – which allows flexibility in adjusting offset intra-operatively. In addition, normalization patterns on the anterior and posterior aspects of the proximal end of the stem facilitate press-fit stability and load transmission.
How long does SECUR-fit last?
Published studies demonstrate clinical performance and survivorship of more than 15 years with OmniFit HA1and up to 10 years with Secur-Fit HA and Secur-Fit Plus.2,3Secur-Fit Advanced also features Stryker’s PureFix HA coating applied proximally, which is supported by over 15 years of clinical success in different stems.1
How many CT scans are in the SECUR-fit®advanced SECUR‑fit advanced technology guide?
SECUR-FIT ADVANCED TECHNOLOGY GUIDE*Based on 556 CT scans +Based on the number available in the proprietary database at the time of the fit study SECUR-FIT®ADVANCED SECUR-FIT ADVANCED TECHNOLOGY GUIDE Clinical advantages of Secur-Fit Advanced